Intro & precautions, Iin nttrro od du uccttiio on n, Ppa atte en ntts s – MicroE 1500S Mercury User Manual

Page 2: Pprre ecca au uttiio on nss

Advertising
background image

IIn

nttrro

od

du

uccttiio

on

n

MicroE Systems was founded to advance encoder technology to
a level never before achieved. Our objective was to design encoder
systems that would be small enough to fit into densely packed OEM
equipment designs, affordable enough for cost-sensitive applications
and easy enough to enable installation, setup and alignment by
assemblers with little training. We are pleased to say that all of
these goals have been realized with the introduction of the Mercury
family of encoders.

Sensor shown

actual size

M10

P

Pa

atte

en

ntts

s

Covered by the following patents: US 5,991,249; EP 895,239; JP 3,025,237; US
6,897,435; and EP 1,451,933. Additional patents and patents pending may apply.

P

Prre

ecca

au

uttiio

on

nss

Follow standard ESD precautions. Turn power off before connecting the sensor.
Do not touch the electrical pins without static protection such as a grounded
wrist strap.

Do not touch the glass scale unless you are wearing talc-free gloves or finger

cots. Please read this installation manual for full instructions.

L

LA

AS

SE

ER

R S

SA

AF

FE

ET

TY

Y IIN

NF

FO

OR

RM

MA

AT

TIIO

ON

N:: M

Me

errc

cu

urry

y &

& C

Ch

hiip

pE

En

nc

co

od

de

err

1

2

This product is sold solely for use as a component (or replacement) in an electronic product; therefore it is not
required to, and does not comply with, 21 CFR 1040.10 and 1040.11 which pertain to complete laser
products. The manufacturer of the complete system-level electronic product is responsible for complying with 21
CFR 1040.10 and 1040.11 and for providing the user with all necessary safety warnings and information.

MicroE encoders contain an infrared laser diode or diodes. Emitted invisible laser radiation levels have been
measured to be within the CDRH Class 1 range, which is not considered hazardous; however, to minimize
exposure to the diverging beam, the encoder sensor should be installed in its operational configuration in close
proximity to the encoder scale before power is applied.

• Invisible laser radiation; wavelength: 850 nm
• Max power 2.4 mW CW (4.8 mW CW for Mercury II™)
• CAUTION – The use of optical instruments with this product will increase eye hazard. DO NOT VIEW

DIRECTLY WITH OPTICAL INSTRUMENTS (MICROSCOPES, EYE LOUPES OR MAGNIFIERS).

• All maintenance procedures such as cleaning must be performed with the MicroE encoder turned off.
• Do not insert any reflective surface into the beam path when the encoder is powered.
• Do not attempt to service the MicroE encoder.

INVISIBLE LASER RADIATION

DO NOT VIEW DIRECTLY WITH OPTICAL

INSTRUMENTS

(MICROSCOPES, EYE LOUPES OR

MAGNIFIERS)

Advertising