5. Periodic Inspection/Maintenance

5-15

A100114

5.5.22 Check O-ring and Needle Valve of Auto-relief Valve and Vaccume relief valve

[3,000 hours or every 3 years ]



When reassembling, apply sufficient grease to O-ring Slot/O-ring and sliding surface.
Use CALTEX MULTIFAK EP1 grease or equivalent. Grease of poor quality will deteriorate the material.



Disassemble and clean the component,

and check O-ring“1”, “2”,“3”and
needle valve“4”. Then, replace O-ring

1”,

2”,

3” and rubber on the needle

valve“4”, if hardened.
(See 5.4)



Replacement of O-ring requires expert

technical knowledge.
So contact directly us or distributor.






5.5.23 Performance Check of Pressure Control Valve

[3,000 hours or every 3 years ]



When reassembling, apply sufficient grease to O-ring Slot/O-ring and sliding surface.

Use CALTEX MULTIFAK EP1 grease or equivalent. Grease of poor quality will deteriorate the material.

<Procedure>

When fully opening the air valves while the

machine is running, make sure that the
discharge pressure gauge shows the figure
between 49-68psi(3.4-4.7bar).

When the pressure is lower than 49psi( 3.4 bar) ,

replace spring“3” with a new one. (See 5.4)

When the indicator shows excessively higher

pressure, you will find that the piston does not
move smoothly due to foreign material and rust
stuck inside valve. In such a case, disassemble
the component for checking and cleaning.


1

2

3

4

1
2

3

4

A070339

1

2

3

4

1

2

3

4

Auto-relief valve

Vaccume relief valve

Advertising