Periodic inspection/maintenance – MMD Equipment 185S-5C2 part 2 User Manual

Page 9

Advertising
background image

5. Periodic Inspection/Maintenance

5-9

5.5.6 Change compressor oil filter

[At 300 hours for the first change and every 1,000 hours thereafter]


Poor quality oil filters do not trap dust sufficiently and will cause damage to the bearings in a short period.

Procedure>

Remove the cartridge“1”, using a filter wrench.

Screw in the new cartridge“1”with the packing“2”coated

slightly with oil. (See 5.4)

After the packing touches the sealing face, further tighten

it by 3/4-1 turn using the filter wrench.

After installing the oil filter, check it for any leak during

operation.




5.5.7 Clean strainer in the scavenging orifice

[Every 500 hours]

Procedure>

Remove the pipe“1”, using a wrench.

First remove the bushing“2”.

Then remove the strainer“3”.

Wash the removed strainer“3”in diesel fuel

and blow out “dust” by air blowing.

After finishing the cleaning, install the

strainer“3” again in the reverse procedure.


1

3 2

Use our genuine oil filter

H000049

1

2

A100110

1

Advertising