6. Maintenance

6-1

D004

W010

TR0093

6.1 Maintenance of Battery



Keep flames away from battery.

Battery may generate hydrogen gas and may explode.

Therefore, recharging should be done at a well-ventilated

place.

Do not spark near the battery nor light a match, nor bring lit

cigarette and match close to the battery.

Do not check the battery by short-circuiting the positive and

negative terminals with a metallic piece.

Never operate the machine nor charge the batteries with the
battery liquid level being kept lower than the "LOWER" level.
Continuing operation at this lower level will cause deterioration of
such parts as pole plates etc., and also it may cause explosion as
well as reduction of battery life. Add distilled water so that the liquid
level may reach the middle level between the "UPPER" and
"LOWER" level without any delay.

Do not charge the frozen battery. Otherwise it may explode. If the
battery is frozen, warm it up until the battery temperature becomes
16°C to 30°C.

Battery electrolyte is dilute sulfuric acid.
In case of mishandling, it could cause skin burning.

When you deal with a battery, please be sure to wear protection
implements, such as protection glasses and a glove.

When such battery electrolyte contacts your clothes or skin,

wash it away with large amount of water immediately.

If the battery electrolyte gets into your eyes, wash it away

immediately with plenty of water and see a doctor at once,
because it is feared that eyesight might be lost.

Dispose of battery, according to the designated regulations.


Handling battery