5. Periodic Inspection/Maintenance

5-1

5.1 Important Items at Periodic Inspection and Maintenance or after

Maintenance

The manual shows proper interval for periodic inspection and maintenance under normally
operating conditions. Inspection and maintenance should be performed more often under
extremely harsh conditions.

Hang a “Now Checking and under Maintenance” tag

Remove the starter key from the starter switch before starting

inspection, and hang up a “Now Checking and under

Maintenance” tag where it can be easily seen. The checker must

keep the key during checking and maintenance.

Remove the negative (–) side cable from the battery.

If the above procedure is neglected, and another person starts

operating the machine during check or maintenance, it could

cause serious injury.

Use tools appropriate for the inspection and maintenance. Any

makeshift or improper tools could cause unexpectedly injury by

their slippage.

SY001

For protecting oil separator from fire accident

Be sure to perform oil change basically according to the

specified interval. But if such oil is found much more

contaminated before the interval, change the oil even before the

specified period comes. In doing so, replace the oil completely

and use our recommended oil.

Be sure to perform following periodic inspection and

maintenance:

1. Check and change compressor oil

2. Change oil separator

Never mix the oil of different brands, or the mixed oil may

deteriorate the oil quality.