2 maintenance of battery, Maintenance/adjustment – MMD Equipment 100S-6B4 User Manual

Page 51

Advertising
background image

6. Maintenance/Adjustment

6-2

6.2 Maintenance of Battery


Do not connect the cables backwards

If a booster cable has to be used or when cables are connected at battery replacement, be careful not

to connect (+) and (–) terminals backwards. A wrong-connection will cause spark and damage

components. Explosion may result.

Handling battery

Keep flames away from battery.

Battery generates hydrogen gas and may explode.

Therefore, recharging should be done at a well-ventilated

place.

Do not allow sparks or flame near the battery.

Do not check the battery by short-circuiting the positive and

negative terminals.

Never operate the machine nor charge the batteries with the

battery liquid level being kept lower than the "LOWER" level.

Continuing operation at this lower level will cause deterioration

of such parts as pole plates etc., and also it may cause

explosion as well as reduction of battery life. Add distilled water

so that the liquid level may reach the middle level between the

"UPPER" and "LOWER" level without any delay.

Do not charge a frozen battery. Otherwise it may explode. If the

battery is frozen, warm it up until the battery temperature

becomes 61°F to 86°F (16°C to 30°C).

Battery electrolyte is dilute sulfuric acid.

In case of mishandling, it could cause skin burning.

When you deal with a battery, please be sure to wear protection

implements, such as protection glasses and a glove.

When such battery electrolyte contacts your clothes or skin,

wash it away with large amount of water immediately.

If the battery electrolyte gets into your eyes, wash it away

immediately with plenty of water and seek medical attention.

Dispose of battery, observing local regulations.

D004

W010

TR0093

Advertising
This manual is related to the following products: