Maintenance, General, Cleaning – Montigo M38ODV ST User Manual

Page 12: Pilot burner adjustment, Gas control valve, Troubleshooting

Advertising
background image

XG0128

Page 12

M38ODV-ST Direct Vented Fireplace

Maintenance

General

„

Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 16.

„

For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.

„

For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.

„

Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
liquids.

„

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any gas
control which has been under water.

CAUTION

Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.

Glass and logs can get very hot. Handle only when cool.

Cleaning

When the fireplace is first activated, there may be some smoking and a
visible film may be left on the glass. This is a normal condition, and is
the result of burningthe protective coatings on new metal.

„

Glass must be cleaned periodically to remove any film (a normal bi-
product of combustion) which may be visible. Film can easily be
removed by removing the door, as shown on page 9. Handle the
door carefully, and clean it with non-abrasive glass cleaners. One of
the most effective products is Kel Kem.

„

Silicone seals on inner door during initial firing will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed by following the steps described above.

„

Use a vacuum cleaner or whisk broom to keep the control compart-
ment, burner, and firebox free from dust and lint.

„

Logs may be cleaned periodically with a vacuum to remove soot.

WARNING:

Do not attempt to clean glass when hot.

Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw.

(See figure 16.)

2. Turn Adjustment Screw until flame is proper size.

(See figure 17).

3. After installing or servicing, leak test with a soap solution with main

burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.

Gas Control Valve

Figure 16.

Sit Nova 820 gas valve for M38ODV-ST.

Manifold Pressure
Test Connection

Pilot Adjustment Screw

Inlet
Pressure

Power
Generator

Wall Switch

Figure 17.

Pilot Burner.

Troubleshooting

Continuous Pilot System Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate Pilot Adjustment Screw. Flame
is decreased by turning adjustment
screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

16.

Main burner will

1. Check wiring (see figure 16)

not light

2. Check wall switch for proper
connection.

M38ODV-ST

Advertising