Page 13

SP28-F2 Modular Series Fireplace

XG0318

Maintenance

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Remove pilot adjuster cap, located on

the gas control valve. Flame is
decreased by turning adjustment screw
clockwise.

Pilot won’t ignite

Disconnect remote wires and try to light
pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

24a/b/c.

Main burner will

1. Check wiring (see figure 24a/b/c)

not light

2. Check wall switch for proper
connection.

EP28-4

Pilot Burner Adjustment

1. Determine which pilot is installed in the fireplace based on figures

25a and 25b.

2. Locate Pilot Adjustment Screw. (See figures 24a, 24b, and 24c.)

3. Adjust pilot key to provide properly sized flame. (See figure 25a or

25b).

4. Replace pilot adjustment cap.

5. After installing or servicing, leak test with a soap solution with main

burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles
appear until the bubbling stops completely.

Figure 25a.

SIT Pilot Burner used on the EP28-F2 model.

Figure 25b.

PSE Pilot Burner used on the EP28-S2 model.