Installation, Installing the fireplace shell – Montigo SP28 F2 User Manual

Page 3

Advertising
background image

Page 3

SP28-F2 Modular Series Fireplace

XG0318

Figure 2.

Framing dimensions.

Installing The Fireplace Shell

The fireplace may be installed in any location that is free of air
conditioning ducts, electrical wiring and plumbing. Safety, as well as
efficiency of operation, must be considered when selecting the fireplace
location. Try to select a location that does not interfere with room traffic,
has adequate ventilation, and offers an accessible pathway for B-Vent &
Combustion Air Kit installation.

The fireplace dimensions are shown below:

Installation

Figure 1.

Fireplace dimensions.

Clearances

The EP-28 Series clearances to combustible materials are:

Top*

12"

Back

0"

Sides

1"

Floor

0"

Mantle**

6"

Recess Depth***

15"

Flue

1"

* Clearance from the top of the fireplace to a

combustible ceiling, within the fireplace
enclosure.

** Refer to page 5.

See Figure 2.

Framing

For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.

37 1/2

15 1/2*

36

*

When sheetrock is not used behind the fireplace,
framing depth may be reduced to 14 3/4"

37 1/2

31 1/4

19

9 1/2

4' B-Vent

14 3/4

C

Top View

Front View

Side View

5" B-Vent

WARNING

:

When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed on
a metal or wood panel extending the full width and depth of the
appliance.

Figure 3.

Corner Installation - framing dimensions.

1

14 3/4

9 1/2

9

38

37

53

1/2

Advertising