Rear panel, Internal adjustments, Fuse – Olson Technology LP-CH-16B User Manual

Page 10: Optical input chart, Return frequency multipliers

Advertising
background image

025-370403 REV X9

Page 10 of 11

REAR PANEL

The RF output connectors are on the rear of the unit. Receiver #1 is on the top. Receiver #3 is on the

bottom.

INTERNAL ADJUSTMENTS

There are 3 jumpers that are accessible from the side that are used to set the receiver input range. The

jumpers can be changed with tweezers or needle nosed pliers. The nominal level for changing jumper posistions is
-3dBm.

FUSE

The module has an internal miniature 3A SB fuse in a holder. The Littelfuse part number is 0454003. The

Olson Technology P/N is 286-000009.

OPTICAL INPUT CHART

The following chart shows the test point readings versus optical input levels.

T.P. Volts

Optical Input mW

Optical Input dBm

3.02

3.02

4.8

2.51

2.51

4

2.00

2.00

3

1.58

1.58

2

1.26

1.26

1

1.00

1.00

0

0.79

0.79

-1

0.63

0.63

-2

0.50

0.50

-3

0.40

0.40

-4

0.32

0.32

-5

0.25

0.25

-6

0.20

0.20

-7

0.16

0.16

-8

0.13

0.13

-9

0.10

0.10

-10

0.08

0.08

-11

0.06

0.06

-12

0.05

0.05

-13

0.04

0.04

-14

0.03

0.03

-15

RETURN FREQUENCY MULTIPLIERS

The Laser Plus system includes 3 receiver/ down converter modules that can be used as part of a return

band frequency multiplier system. This system can quadruple the bandwidth of a new or existing return link. Olson
Technology builds up converters to fit inside the nodes of several manufacturers. Consult the factory for the latest
list of compatible nodes.

See the LPDC-212 / LPDC-234 instruction manual, OT # 025-370447, for more details.

Advertising
This manual is related to the following products: