LPOR-304 Operating Instructions

Revision A

4 June 2006

PAGE 7 of

10

OPTICAL BEHAVIOR

Six of the eight DIP switches (2, 3, 4, 6, 7, and 8) control the optical behavior of the unit. Switches 2

and 3 are used to set the wavelength of the two receivers. The user can select either 1310 nm or 1550 nm
independently for each channel. Switches 4, 6, 7, and 8 determine the optical input levels where the
receiver alarms switch. See Table 3 for details.

Function Switch

The pushbutton cycles through the following states by holding the button down for 0.5 second or

more:

• Automatic Mode (Redundant with Automatic Switchover)
• Force PRIMARY Rx Active
• Force SECONDARY Rx Active

(then cycle back to Automatic Mode)

The current state of the unit is stored in E

2

PROM in case of power failure. If power does fail, the last

valid state will be restored when power is restored.

Table 3 – Optical Thresholds

Switch 6 Switch 7 Switch 8 Switch 4 Green to Red Threshold

Red to Green

Threshold

OFF

OFF

OFF

OFF

-19 dBm

-16 dBm

OFF

OFF

OFF

ON

-19 dBm

-18 dBm

OFF

OFF

ON

OFF

-17 dBm

-14 dBm

OFF

OFF

ON

ON

-17 dBm

-16 dBm

OFF

ON

OFF

OFF

-15 dBm

-12 dBm

OFF

ON

OFF

ON

-15 dBm

-14 dBm

OFF

ON

ON

OFF

-13 dBm

-10 dBm

OFF

ON

ON

ON

-13 dBm

-12 dBm

ON

OFF

OFF

OFF

-10 dBm

-7 dBm

ON

OFF

OFF

ON

-10 dBm

-9 dBm

ON

OFF

ON

OFF

-7 dBm

-4 dBm

ON

OFF

ON

ON

-7 dBm

-6 dBm

ON

ON

OFF

OFF

-4 dBm

-1 dBm

ON

ON

OFF

ON

-4 dBm

-3 dBm

ON

ON

ON

OFF

-1 dBm

+2 dBm

ON

ON

ON

ON

-1 dBm

0 dBm