Rx1 and rx2 leds (independent), Mode led (independent), Rx1 and rx2 leds (redundant) – Olson Technology LP-OR-304 User Manual

Page 8: Mode led (redundant)

Advertising
background image

LPOR-304 Operating Instructions

Revision A

PAGE 8 of

10

4 June 2006

INDEPENDENT MODE DETAILED OPERATION

Rx1 and Rx2 LEDs (Independent)

In the independent mode, the individual receiver LEDs have three display states. They will never be

orange.

Mode LED (Independent)

In the independent mode, the mode LED blinks green for 0.25 second every 3 seconds to give an

indication that the unit is powered.

REDUNDANT MODE DETAILED OPERATION

Rx1 and Rx2 LEDs (Redundant)

The individual receiver LEDs have four display states. They blink to indicate an unacknowledged

fault on that input.

Mode LED (Redundant)

When operating as a redundant receiver, the mode LED has three display states. It is never turned off.

Table 4 – Independent Rx1 and Rx2 LED Conditions

DISPLAY

CONDITION

OFF

Rx disabled

GREEN

Rx input OK. Unit output from this Rx.

RED

Rx input fault (Optical input is below preset threshold)

Table 5 – Redundant Rx1 and Rx2 LED Conditions

DISPLAY

CONDITION

Off

Rx Disabled via gain control (Will never blink)

Green

Rx input Ok. Unit output from this Rx.

Orange

Rx input Ok. Unit output from other Rx.

Red

Rx input fault (Optical input is below preset threshold)

Table 6 – Redundant Rx Mode LED Conditions

DISPLAY

CONDITION

NOTES

Green

Primary Rx Input OK. Redundant
Operation Enabled.

Both receivers must be enabled. This state is
independent of the presence of backup optical input.

Orange

Redundant Operation Disabled

This can be from one of two causes:

Either one or both receivers disabled with gain control.

Non-redundant operation selected with function switch.

Red

Redundant Operation Enabled

Automatic transfer has occurred. Output of unit is
backup input whether or not optical signal is present on
this input.