Digital room sensor, Appendix, Operator interface 10 – Orion System Digital Room v.1 User Manual

Page 10: Hi (v av ) lo w (vv t ) velocity, Override alarm, Sensor technical guide

Advertising
background image

DIGITAL ROOM SENSOR

Operator Interface

10

Appendix

EXPANSION

D'STAT

SPACE SENSOR

POWER / COMM

STAT

M

A

DE

IN

US

A

WA

TT

M

A

ST

ER

C

O

N

T

R

O

L

S

IN

C

HI

(V

AV

)

LO

W

(VV

T

)

VELOCITY

AI

RF

L

O

W

WDO

G

A

D

D

R

ESS

OF

F

O

N

EP

RO

M

PAL

ACTUATOR

485

REC

DRV

EEPROM

93C66

(-

)L

O

GND

OUT

IN

AIR FLOW

SENSOR

OE742/OE744 VAV/Zone Controller Actuator Package

Display

Override

OVERRIDE

ALARM

NOTE: If Also Using An OE256-01
Or OE256-02 C

Sensor, T

Connects To The VAV/Zone

Controller First Using A TSDRSC
Cable Of The

Length. The

Digital Room Sensor Then Connects
To The CO Sensor With Another
TSDRSC Cable.

O

2

2

he CO

Sensor

Required

The Total Length Of

Cable For Either One Or Both Cables
Combined Cannot Exceed 160 Feet.
See The
For Further Wiring Details.

2

CO

2

Sensor Technical Guide

OE217-00

Digital Room Sensor

TSDRSC Cable

OE217-00 Or OE217-01

Digital Room Sensor

OE332-23E-VCMX

VCM-X E-BUS Controller

TSDRSC Cable

Display

Override

OVERRIDE

ALARM

NOTE: If Also Using An OE256-01
Or OE256-02 CO Sensor, The CO
Sensor Always Connects To The
VCM-X Controller First Using A
TSDRSC Cable Of The Required
Length. The Digital Room Sensor
Then Connects To The CO Sensor
With Another TSDRSC Cable.
The Total Length Of Cable For Either
One Or Both Cables Combined
Cannot Exceed 160 Feet. See The

For

Further Wiring Details.

2

2

2

CO

2

Sensor Technical Guide

RELAY CONTACT
RATING IS 1 AMP
MAX @ 24 VAC

RS-485 COMMUNICATION LOOP. WIRE
“R” TO “R”, “T” TO “T” “SHLD” TO “SHLD”

FAN

RELAY 2

RELAY 3

RELAY 4

RELAY 5

RELAY
COMMON

IC DIGITAL

SENSOR

2

IC

EXPANSION

2

STATIC

PRESSURE

AI1 = SPC (SPACE TEMPERATURE SENSOR)

AI2

AI3

AI4

AI5

AI7

A01

A02

= SAT (SUPPLY AIR TEMPERATURE SENSOR)
= RAT (RETURN AIR TEMPERATURE SENSOR)
= OAT (OUTDOOR AIR TEMPERATURE SENSOR)
= SUCTION PRESSURE SENSOR
= SPACE TEMPERATURE SENSOR SLIDE ADJUST

OR VOLTAGE RESET SOURCE

= ECONOMIZER (2-10 VDC OUTPUT)
= SUPPLY FAN VFD (0-10 VDC OUTPUT)

ANALOG INPUT JUMPER SETTINGS
MUST BE SET AS SHOWN FOR
PROPER OPERATION

24 VAC POWER ONLY

WARNING! POLARITY MUST BE OBSERVED

OR THE CONTROLLER WILL BE DAMAGED

www.orioncontrols.com

AI1

AI2

AI3

AI4

THERM

THERM

THERM

THERM

THERM

THERM

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

0-10V

0-10V

0-10V

0-10V

0-10V

0-10V

0-5V

0-5V

0-5V

0-5V

0-5V

0-5V

AI5

AI7

ANALOG INPUT

JUMPER

SETTINGS

WattMaster Label

#LB102033-01

OE332-23-VCMX-A VCM-X CONTROLLER

WA
RN
IN

G

OBSERVE

POLARITY

RELAY CONTACT
RATING IS 1 AMP
MAX @ 24 VAC

RS-485 COMMUNICATION LOOP. WIRE
“R” TO “R”, “T” TO “T” “SHLD” TO “SHLD”

FAN

RELAY 2

RELAY 3

RELAY 4

RELAY 5

RELAY
COMMON

IC DIGITAL

SENSOR

2

IC

EXPANSION

2

STATIC

PRESSURE

ANALOG INPUT JUMPER SETTINGS
MUST BE SET AS SHOWN FOR
PROPER OPERATION

24 VAC POWER ONLY

WARNING! POLARITY MUST BE OBSERVED

OR THE CONTROLLER WILL BE DAMAGED

AI1

AI2

AI3

AI4

THERM

THERM

THERM

THERM

THERM

THERM

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

0-10V

0-10V

0-10V

0-10V

0-10V

0-10V

0-5V

0-5V

0-5V

0-5V

0-5V

0-5V

AI5

AI7

ANALOG INPUT

JUMPER

SETTINGS

WattMaster Label
#LB102073-01-A

Rev.: 1A

www.aaon.com

www.orioncontrols.com

VCM-X MODULAR E-BUS CONTROLLER

Orion No.:OE332-23E-VCMX-MOD-A

AAON No.:

V07150

AI1 = SPC (SPACE TEMPERATURE SENSOR)

AI2

AI3

AI4

AI5

AI7

A01

A02

= SAT (SUPPLY AIR TEMPERATURE SENSOR)
= RAT (RETURN AIR TEMPERATURE SENSOR)
= OAT (OUTDOOR AIR TEMPERATURE SENSOR)
= SUCTION PRESSURE SENSOR (FROM EXP. MODULE)
= SPACE TEMPERATURE SENSOR SLIDE ADJUST

OR VOLTAGE RESET SOURCE

= ECONOMIZER (2-10 VDC OUTPUT)
= SUPPLY FAN VFD (0-10 VDC OUTPUT)

LED BLINK CODES

LED NAME

STATUS1 STATUS2

NORMAL OPERATION

0

1

SAT FAIL

1

2

OAT FAIL

2

2

SPC FAIL

3

2

MODULE ALARM

4

2

MECH COOL FAIL

1

3

MECH HEAT FAIL

2

3

FAN PROOF FAIL

3

3

DIRTY FILTER

4

3

EMERGENCY SHUTDOWN

5

3

LOW SAT

1

4

HIGH SAT

2

4

CONT. TEMP COOL FAIL

3

4

CONT. TEMP HEAT FAIL

4

4

PUSH BUTTON OVR

1

5

ZONE OVR

2

5

OUTPUT FORCE ACTIVE

0

6

E-BUS

CONNECTOR

Figure 17: Digital Room Sensor to VAV/Zone Controller Wiring

Figure 18: Digital Room Sensor to VCM-X E-BUS Controller Wiring

Advertising
This manual is related to the following products: