Part b – installation, 6safety information – Osburn OB04002 User Manual

Page 33

Advertising
background image

Stratford

Fireplace Installation and Operation Manual

_____________________________________________________________________ 33

PART B – INSTALLATION

Install the fireplace only as described in these instructions and using only components from the
chimney manufacturers listed in table 2.

Parts Required

Stratford Fireplace

Insulated chimney made by the manufacturers listed in table 2, with the corresponding
specifications :

Chimney lengths

Elbows (where necessary)

Associated components as per these installation instructions.

Additional Equipment (optional)

Forced Air Distribution Kit

Hot Air Gravity Distribution Kit

Fresh Air Intake Kit

Fire Screen

6

SAFETY INFORMATION

6.1

SUMMARY OF INSTALLATION CAUTIONS AND WARNINGS

THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE
ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S
MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).

MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH CHANGES ARE
PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE
TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).

CONNECTION BETWEEN A 2100 INSULATED CHIMNEY AND A LISTED STAINLESS STEEL
CHIMNEY LINER IS ALLOWED IF A LISTED CONNECTOR IS USED. FOLLOW INSTRUCTIONS IN
SECTION 9.9 FOR THAT KIND OF INSTALLATION.

IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.

DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.