Stratford

Fireplace Installation and Operation Manual

64 _____________________________________________________________________

8.7

ANGLED WALL RADIATION SHIELD

When passing through a combustible wall with the chimney at a 30

°

or 45

°

angle (30

°

or 45

°

in

Canada and 30

°

only in the USA), an angled firestop or wall radiation shield provided by the

chimney manufacturer must be installed. Only one is required. Follow the chimney manufacturer’s
installation instructions.

In cold climate locations, it is recommended that you use the insulated wall radiation shield since
it will maintain the home’s thermal barrier.

A

INSULATED WALL RADIATION SHIELD

B

GYPSUM BOARD

C

INSULATED WALL

8.8

CHIMNEY SUPPORT INSTALLATION

8.8.1

UNIVERSAL ROOF SUPPORT

This support has three possible uses:

1.

It must be used on a roof to support the chimney.

2.

It may be used on a floor, ceiling or roof above an offset to support the chimney above the
offset.

3.

It may be used on a floor, ceiling or roof as a supplementary support.

For roof support installation, refer to the instructions provided with the support by the chimney
manufacturer. Many manufacturers will provide the maximum height of chimney that can be
supported by the support. Make sure you respect those parameters.