Osburn OB04002 User Manual

Page 65

Advertising
background image

Stratford

Fireplace Installation and Operation Manual

_____________________________________________________________________ 65

8.8.2

UNIVERSAL OFFSET SUPPORT

This support is used to support the chimney above an offset. When the chimney offset is used to
pass through a wall, this support may be used on the wall to support the chimney. For offset
support installation, refer to the instructions provided with the support by the chimney
manufacturer. Many manufacturers will provide the maximum height of chimney that can be
supported by the support. Make sure you respect those parameters.

8.9

INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION

WARNING:

BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE

INSPECTED BY A QUALIFIED SWEEP.

The following requirements must be respected:

1.

The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose
or missing bricks that could inhibit correct installation of the liner.

2.

The clearance to combustible must be a minimum of 1" between the outside of the masonry
and any wood framing or loose insulation.

3.

The chimney must be built in accordance with the current building code.

4.

No other appliance can be connected to the same chimney.

Installation:

The chimney must be relined with a stainless steel liner of the same diameter as the outlet of
the fireplace. For connection at 30

°

or 45° angle, a special connector (B) must be used to connect

the liner (C) to the insulated chimney (A). Verify availability and installation instructions for this
connector with the chimney manufacturer.

Advertising
This manual is related to the following products: