Use lan port, How to use executive buttons, Run/stop – OWON VDS Series User Manual

Page 33: Single trigger, Connect directly via a lan cable

Advertising
background image

It's a very useful and quick way to apply a set of pre-set functions to the incoming signal, and display the best possible viewing waveform of the
signal and also works out some measurements for user as well.

The details of functions applied to the signal when using AutoSet are shown as the following table:

Function Items Setting

Acquisition Mode Current

Vertical Coupling DC

Vertical Scale

Adjust to the proper division.

Horizontal Level Middle

Horizontal Sale

Adjust to the proper division

Trigger Type

Current

Trigger Source

Show the minimum number of
channels.

Trigger Coupling Current

Trigger Slope

Current

Trigger Level

Mid-point Setting

Trigger Mode

Edge

Display Format

YT

Run/Stop:

Enable or disable sampling on input signals.

Single Trigger

: You can set the trigger mode as single directly, so

when trigger occurs, acquire one waveform then stop.

Keyboard Shortcuts

Enter: Auto set
Space: Run/Stop



16.Use LAN Port

Using the LAN port, the oscilloscope could be connected to a PC directly or through a router. Below introduces these two kind of connection
methods.

Connect directly via a LAN cable

1. View the network parameters of the computer

View the IP address of the computer to connect to. Assume the IP address is 192.168.1.71.

2. Set the network parameters of the oscilloscope

(1) Connect via USB and enter the menu: Use the supplied USB cable to connect the oscilloscope with a PC through their USB ports

.

After connecting successfully, click

to show Function menu, choose "Utility", click "Network".


(2) Set IP and port of the oscilloscope: In Network menu, click "OK" to enter MachineNetSetting.

Choose the oscilloscope to be connected from the list. If it's not in the list, click "Refresh" to refresh the list.
Set IP, the first three bytes should be same as the IP address of the computer in step 1, the last byte should be different. Here, we set it to
192.168.1.72. The range of the port value is 0~4000, here we set it to 3000.