Required adjustment for up to 180°F (82°C) water temperature settings

WARNING: Refer to scald potential warnings on page 4 before

making adjustment. Changing this setting is done at your own risk.

NOTICE: Raising the water temperature setting above 120ºF (49ºC)
will lead to increased lime buildup. Error code (1L) will be displayed
when lime build up occurs. Contact your dealer for service when this
error code is displayed.

DO NOT alter the #4 DIP Switch if the setting of up to 180°F (82°C) is
not required.

Follow the instructions below if it is determined that a setting of up to
180°F (82°C) is required.

Turn off remote control. Turn off the gas and water shutoff valves.

Remove the front cover.

Find the DIP Switch #4 located at the top left hand side of the PCB. (See
illustration to the right for DIP Switch location)

Change the DIP Switch #4 setting to the “ON” position. DO NOT alter any
other DIP Switch. The LED on the PCB is flashing. At the same time, the
display of the Main Remote Control starts to flash.

Press the “Max” button on the left hand side of the PCB for more than 1
second. The LED on the PCB starts illuminating continuously. At the same
time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter
any other DIP Switch. The LED on the PCB will stop illuminating. At the
same time, the display of the Main Remote Control will turn off.

Attach the unit’s front cover.

Turn on the remote control, gas and water shutoff valves.

Check and ensure safe operation and performance of the water heater.

See steps below to LIMIT maximum water temperature setting to 120 (49°C).

Follow first four bullets points listed above, then continue as listed below:

Press the “Min.” button on the left hand side of the PCB for more than 1
second. The LED on the PCB starts illuminating continuously. At the same
time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter
any other DIP Switch. The LED on the PCB will stop flashing. At the same
time, the display of the Main Remote Control turn off.

Attach the unit’s front cover.

Turn on the remote control, gas and water
shutoff valves.

Check and ensure safe operation and
performance of the water heater.

!

ON

1

2

3

4

DIP1

ON

OFF

1

2

3

4

SW1

SW2

SW3

ON

1

2

3

4

DIP1D

IP

1

ONO

N

OFFO

FF

1

2

3

4

Setting during adjustment

to DIP Switch #4

for temperature.

ON

1

2

3

4

As set from factory

ON

1

2

3

4

ON

1

2

3

4

Setting after adjustment

to DIP Switch #4

for temperature.

Location of DIP Switches on PC Board.

Temperature Setting DIP Switch Adjustment

The content on this page is intended for use by qualified

installation/service personnel ONLY.

ON

1

2

3

4

DIP1

ON

OFF

1

2

3

4

SW1

SW2

SW3

“Max”
Button

“Min.”

Button

LED

DIP

Switches

WARNING: Improper adjustment, alteration,

service or maintenance can cause property damage,
personal injury, or death.

Time/Temperature Relationship in Scalds

DANGER: Hotter water increases

the potential for Hot Water SCALDS.

!

120°F (49°C)

More than 5 minutes

125°F (52°C)

1 ½ to 2 minutes

130°F (54°C)

About 30 seconds

135°F (57°C)

About 10 seconds

140°F (60°C)

Less than 5 seconds

145°F (63°C)

Less than 3 seconds

150°F (66°C)

About 1 ½ seconds

155°F (68°C)

About 1 second

Table courtesy of Shriners Burn Institute