Paloma PH2-20 Direct Vent User Manual

Page 23

Advertising
background image

23

For increased energy efficiency, use pipe
insulation. Please install the insulation
according to the diagram above, making sure

to insulate all the way to the top. Do not
cover any drain or pressure relief valve(s).

Do’s

Do follow all installation instructions

covered in this manual.

Do check inlet gas pressure to ensure

that it is within the range specified on
the rating plate.

Do provide adequate air for combustion
and ventilation as discussed in the Use &
Care Manual and the National Fuel Gas
Code (CSA B149 in Canada).

Do maintain proper clearances to
combustibles and non-combustibles as
specified on the nameplate.

Do ensure that the venting system complies
with the guidelines found in the Use &
Care Manual and National Fuel Gas Code
(CSA B149 in Canada).

Do contact local gas company to ensure gas

meter and gas piping are adequately sized.

Do use teflon tape on water line

connections and fittings.

Don’ts

Don’t block or restrict Air Intake Openings
on vent termination.

Don’t remove the front cover unless
absolutely necessary. This should only be
done after being examined by a qualified
service technician.

Don’t install this product where standing
water may occur.

Don’t use pipe dope on water line
connections and fittings.

During Installation of this water heater…

Hot and Cold Pipe Insulation Installation

Insulation Blankets

Insulation blankets, available to the general
public for external use on gas water heaters,
are not necessary. The purpose of an
insulation blanket is to reduce the standby
heat loss encountered with storage tank
heaters. This water heater does not store water
making an insulation blanket unnecessary.

The manufacturer’s warranty does not cover
any damage or defect caused by installation,
attachment or use of any type of energy
saving or other unapproved devices (other
than those authorized by the manufacturer)
into, onto or in conjunction with the water
heater. The use of unauthorized energy saving
devices may shorten the life of the water
heater and may endanger life and property.

The manufacturer disclaims any responsibility
for such loss or injury resulting from the use
of such unauthorized devices.

CAUTION: If local codes require the
application of an external insulation
blanket to this water heater, pay careful
attention to the following so as not to
restrict the proper function and operation
of the water heater:

Do not cover the air inlet, flue outlet or

operating and warning labels attached to
the water heater or attempt to relocate them
on the exterior of insulation blanket.

WARNING: If local

codes require external
application of
insulation blanket kits
the manufacturer’s
instructions included
with the kit must be
carefully followed.

NOTICE: The hot
and cold pipes should
be insulated as shown
to provide additional
freeze protection.

WARNING: In case

the pipe insulation is
not rated for the
appropriate weather
conditions install
electric heat tracing or
equivalent to prevent
freezing of the pipes.
Do not insulate or
block drain valve on
the hot outlet fitting. If
the pipes are allowed
to freeze, the water
heater and the pipes
may malfunction or
leak due to freezing
water.

Water Inlet

Water Outlet

To Drain

Water Inlet

Cold Water

Service Valve

Hot Water

Service Valve

Pressure

Relief Valve

Pipe Insulation

Advertising