Error Code Guide:

When an error code is displayed:

Close the hot water faucet, turn off the switch on the remote

control.

Wait for about 5 minutes before turning the switch on

again.

Open the hot water faucet.

If the error code remains in the display:

Close the hot water faucet and turn off the switch on the

remote control.

Take the proper action shown below and attempt operation

of the appliance again.

If the error code is still shown:

Turn off the hot water faucet and turn off the switch on the

remote control.

Take note of the error code displayed and call the customer

service assistance number in the “If You Need Service”
section of the manual on the back cover.

Notice: If an error code other than those listed below is
displayed, immediately turn off the hot water faucet, take note
of the error code, turn off the switch on the remote control and
call the customer assistance number.

CAUTION: For your safety, DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other
safety devices. Refer repairs to qualified service personnel.

CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING.

32

Error Code

Possible Cause

What To Do

11

The Gas Shutoff Valve is not opened
completely.

Open the Gas Shutoff Valve

completely.

12

Gas Service has been interrupted.

LP Gas is running low. (LP models only)

Contact Gas Utility Company.

Fill up LP Gas container or replace

with a new cylinder of LP Gas.

15

The hot water faucet is not opened enough.

Open the faucet more to secure

enough volume.

05

(Every 60 seconds you hear

an alarm or when the faucet is

closed, the alarm stops.)

Air intake or vent termination may be
blocked.

The vent pipes on the concentric vent
termination may not be connected properly.

Remove any obstructions on the air

intake or vent termination.

Contact a dealer for service.

13

If the error code is still displayed after taking
the above steps.

Contact a dealer for service.

1L

Water heater has build up of lime deposits.

Contact a dealer for service.