Paper, Power adaptor, Multiple interface issue – Posiflex AURA-9000 User Manual

Page 15: Upos concerns

Advertising
background image

Page 15

PAPER

PAPER TYPE

THERMAL ROLL PAPER

Paper roll formation

External side is heat-sensitive side

Paper width

83/80 (or 58) + 0 / - 1 mm

Paper roll outer diameter

80 mm max.

Paper roll inner diameter

12 + 1 / - 0 mm

Paper thickness

60 ~ 80 um

POWER ADAPTOR

ITEM

REQUIREMENT

Input voltage

100 V AC ~ 240 V AC

Input frequency

47~63 HZ

Input current

2.5 A MAX.

Output voltage

+ 24 V DC

Output power

60 W

Output regulation

+ / - 5 %

MTBF

30,000 HRS

EMI standards

CISPR22, EN55022 Class B

MULTIPLE INTERFACE ISSUE

For model Aura-9000, there is only 1 connector for host connection through
USB. For Aura-9000P, there are 2 connectors for host connection: USB and in
addition to Parallel port. For Aura-9000S, there are 2 connectors for host
connection: USB Port and in addition to the Serial port. For Aura-9000L, there
are 2 connectors for host connection: USB and in addition to the LAN port.
Please always connect only one interface at a time. Simultaneous multiple
host connections could result in unexpected results!

UPOS CONCERNS

The UPOS compliance and WEPOS compliance ability of the Aura-9000
series dictates the printer to perform certain internal affairs such as counter
refreshment periodically. When the printer is engaged in such operations there
will be a brief period of time that the printer is busy without externally
apprehensible cause. In other words, the printer will lit the ERROR LED
briefly once in a while even when no external communication is in process and
that is definitely normal.


Advertising