P16

Transmitter Setup:

Press and hold power button 3 seconds, the OLED window comes on.

Frequency setup: To let the transmitter IR receiving window face to the receiver IR data transfer

window, then press “SYNC” button, the transmitter will receive the frequency / channel dada from the
receiver, simultaneously the OLED displays the same frequency / channel as the receiver .

Operating menu of the Receiver

EXIT

SET

DISPLY

SET

FREQUENCY

/

CHANNEL

Switching between the
standard displays

Current standard display;
FREQ: display the
FREQUENCY

/

:FREQUENCY,CHANNEL

CHANNEL: display the CHANNEL;SET:
store setting.

STORED

GROUP

SET

01

/

10

Group display

Group selection

/

:01-10group, group selection, SET:

store setting.

STORED

LEVEL

SET

-06dB

/

18dB

Setting the audio output level

The lowest output level

/

:-06-18dB

-06dB: Lowest output level ;0dB: Default
output level ;18dB: Maximum output level
;SET: store setting.

STORED

SQELCH

SET

0dB

/

50dB

Adjusting the squelch
threshold

Minimum Squelch

/

:0dB~50dB

50dB: Maximum Squelch ; 0dB: Minimum
Squelch ; 15dB: Default Squelch ; SET:
store setting.

STORED

LOCK

SET

OFF

/

ON

Activating the lock mode

Unlock receivers
Lock mode activated or
deactivated

/

:ON, OFF

ON :Lock mode activated ; OFF: Unlock
mode activated ; SET: store setting.

STORED

PILOT

SET

OFF

/

ON

Pilot

Switch on

/

:ON, OFF ;ON:Switch off ;

OFF:Switch on ; SET:store setting.

STORED

BANK