MEMORIES

The main parameters of the image may be saved in distinct

groups of values (known as ‘Memories’); these parameters

can subsequently be applied all together by way of a single

command.

There are 3 distinct Memories (Memory 1, Memory 2, Memory

3) for each of the 25 signal types managed:

making a total of 75 different available Memories.

The image parameters that can be saved/recalled by the Me-

mories management system are the following:

Image

Picture

BRIGHTNESS

ASPECT

CONTRAST

COLOR TEMP.

COLOR

OVERSCAN

TINT

GAMMA

SHARPNESS

FILTER

SHARPNESS MODE

VIDEO TYPE

NOISE REDUCTION

5 COMP/RGB(YCrCb 15KHz)

5 COMP/RGB(RGB 15KHz)

6 COMP/RGB(YCrCb 15KHz)

6 COMP/RGB(RGB

15KHz)

5 COMP/RGB(YCrCb 32KHz)

5 COMP/RGB(RGB 32KHz)

6 COMP/RGB(YCrCb)

6 COMP/RGB(RGB)

7 COMP/RGB(YCrCb 15KHz)

7 COMP/RGB(RGB 15KHz)

8 COMP/RGB(YCrCb 15KHz)

8 COMP/RGB(RGB

15KHz)

7 COMP/RGB(YCrCb)

7 COMP/RGB(RGB)

8 COMP/RGB(YCrCb)

8 COMP/RGB(RGB)

9

GRAPHICS RGB

11 DVI-D (RGB)

12 HDMI

1 VIDEO

2 VIDEO

10

GRAPHICS RGB

11 DVI-D (YCrCb)

3 S-VIDEO
4 S-VIDEO

Some of these parameters may not be available for certain

inputs or certain input signals, as indicated in Tables 4 and 5.

The menu page for the Memories management functions is

activated by pressing the key on the remote control or the
fl key on the keypad (Fig.30).

ZOOM

��

���

Fig.30

The operations that can be performed on each memory se-

lected are described here below.

SAVE A MEMORY

To save the current values of the image parameters in Memory

1, use the · and ‚ keys to move to line ‘1’ and then open the pull-
down menu by pressing the fl key (Fig.31). Then select the

option ‘Save current settings’. To confirm that the operation has

been completed successfully, the message ‘Current settings

saved in Memory 1’ is displayed at the bottom of the screen and

the letter ‘S’ appears to the left of the memory name. The same

procedure is used to save parameters in Memories 2 and 3.

0 Auto

3

S MEMORIA 1

Memories

Save current settings

Save initial settings

Rename

2

I

1

S

Fig.31

RECALL A MEMORY
To recall a Memory, select the desired line and press ‡. The

parameters saved in the selected Memory will be applied to

the image displayed and a message will appear to confirm

the operation ‘Memory 1 recalled’. The Memory recalled will

be associated with the source and signal type, and will be

automatically recalled every time that particular source and

signal type combination is selected.