Connectors, Comm-ports, 3 connectors – Sundance SMT401 User Manual

Page 6: Ports, Omport, Ocations on, Smt401

Advertising
background image

Released

Page 6 of 21

SMT401 PMC TIM Carrier User Guide

Document Name:

SMT401 User Guide V1.2.doc

Issue : 02

Rev.: 1.11

3 Connectors

This chapter details the connectors on the SMT401.

3.1 Comm-ports

The SMT401 has connections for up to six comm-ports, but usually only
there will only be five comm-ports available to the user, since one comm-port
is dedicated to the host comm-port interface (see figure 1.1, page 7).

Figure 3.1 shows the locations of the various connectors, and which C4x
comm-port they correspond to. C

n

denotes the comm-port number as seen

by the C40 TIM:

J2

J1

J10

J12

J13

(PMC connectors on this side)

C

0

C

4

C

1

C

2

C

5

J11

J15

J14

JTAG IN
Port

JTAG OUT
Port

C

3

J11 is used as the Host Comm port and is not normally available for connection

Figure 3-1: Comm-port Locations on SMT401

As with all C4x comm-ports, it is important to observe the rule governing the
connection of RTO and RTI comm-ports:

Important Note

J10, J12, are RTO comm-ports

J11, J13 are RTI comm-ports

Do not connect a RTO comm-port to another

RTO comport

Do not connect a RTI comm-port to another RTI

comport

Failure to observe these rules can result in

permanent damage.

Product Name:

SMT401

Revision Date:

07 December 2004

Author:

Mark I. Cartlidge (Updated by SM, added JTAG slave section)

Original Date:

12 May 1999

Advertising