Tecfluid SC-250 User Manual

Page 2

Advertising
background image

2

Technical Data

Accuracy:

Based on VDE / VDI 3513

± 2,5% of full scale value.

On

Order:

± 1,6% of full scale value.

Rangeability: 10:1

Scale length: ~100 mm.

Scales:

Direct in l/h etc. or in %.

Mounting: Vertical.

Rising

flow

direction.

Pipe fittings: DIN flanges.

Others

on

order.

Materials:

EN 1.4404 (AISI-316L), PVC, PTFE,

PP.

Working pressure:

- SC-250 EN 1.4404

PN 40

DN 15...DN 50

PN 16

DN 65...DN 150

- SC-250 PVC / PTFE / PP

PN 16

DN 15...DN 50

PN 10

DN 65...DN 150

- SC-250 EN 1.4404+PVC / PTFE / PP

PN 40

DN 15...DN 40

PN 16

DN 50...DN 125

PN 10

DN 150

Others on order.

Working temperature:

Standard:

- EN 1.4404:

-50ºC...+200ºC

- PVC:

0ºC...+ 50ºC

- PTFE:

-20ºC...+150ºC

- PP:

-20ºC...+ 85ºC

With thermal separator:

- EN 1.4404:

-180ºC...+400ºC

Indicator housing:

IP 65, Polyamide 11 covered aluminium

Mounting length:

DN 15...DN 125:

250 mm.

DN 150:

300 mm.

Conforms with the Pressure Equipment
Directive 97/23/EC.

This equipment is considered as being a pressure
accessory and NOT a safety accessory as defined
in the 97/23/EC directive, Article 1, paragraph
2.1.3.

Optional limit switches:

- SC-AMM

Micro-switch mounted in the indicator
housing.

• Maximum current: 3A.

• Maximum voltage: 250 Vac.

Conforms with Directive 73 / 23 / EEC
(Low Voltage)

- SC-AMD

DIN 19234 (NAMUR) vane operated
inductive detector, mounted in the
indicator housing.

• Nominal voltage: 8,2 Vdc

Conforms with Directive 89/336/EEC
(EMC)

Optional transmitters:

- TKEX Angular position converter, coupled to the

indicating system of the flow meter, which

gives a linear output 0...4-20 mA

proportional to the measured flow rate.

• Power supply: 12,7...36 Vdc.

• Output signal: 0...4-20 mA.

• Electrical connection: 2, 3 ó 4 wire.

Certified by PTB to EEx ia IIC T6.

- TEH3

A position transducer with

analog output for 2 or 4 wire connection.

• Power supply: 10 to 50 Vdc (2 wire)

220 Vac, 240 Vac, 110 Vac, 24 Vac
50/60 Hz (4 wire)

• Output signal: 4-20 mA.

Conforms with Directives 73 / 23 / EEC
(Low voltage) and 89/336/EEC (EMC)

- TTEH3

A position transducer with analog

output and totalizer for 2 or 4 wire

connection.

• Power supply: 10 to 50 Vdc (2 wire)

220 Vac, 240 Vac, 110 Vac, 24 Vac
50/60 Hz (4 wire)

• Output signal: 4-20 mA.

Conforms with Directives 73 / 23 / EEC
(Low voltage) and 89/336/EEC (EMC)

- TEH3/EEX

A position transducer with

analog output for 2 wire connection.

• Power supply: 10 to 24 Vdc

• Output signal: 4-20 mA.

Conforms with Directives 89/336/EEC
(EMC) and 94 / 9 / CE (ATEX)

Certified by LOM to EEx ia IIC T4

- TTEH3/EEX A position transducer with analog

output and totalizer for 2 wire connection.

• Power supply: 10 to 24 Vdc

• Output signal: 4-20 mA.

Conforms with Directives 89/336/EEC
(EMC) and 94 / 9 / CE (ATEX)

Certified by LOM to EEx ia IIC T4

- TP1200

Pneumatic transmitter that gives an
output of 3-15 psi or 0,2-1 bar
proportional to the measured flow rate.

• Air supply: 1,4 bar ±0,1 bar

!