Technical data – Tecfluid TM Series User Manual

Page 11

Advertising
background image

11

6

TECHNICAL DATA

Accuracy
± 0.5% measured value

Repeatability
± 0.1% measured value

Temperature
Process temperature:

-50 ºC … +170 ºC

Ambient temperature:

-20 ºC ... +60 ºC

Connections
EN 1092-1 flanges. Other flange standards.
BSP or NPT threaded connections
Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP®

Materials
Body: EN 1.4404 (AISI 316L)
Propeller: EN 1.4016 (AISI 430)

Working pressure
DN15 ... DN50: PN40
DN65 ... DN150: PN16
Others on request

Electrical connection
By means of IP65 connector.

Signal amplitude
> 15 mV, proportional to flow rate

Recommended cable
Shielded bifilar up to 30 m length.

NOTE: For distances up to 100 m the APTM44 amplifier shall be used.

Conforms with the Pressure Equipment Directive 97/23/EC.

This equipment is considered as being a pressure accessory and NOT a safety accessory
as defined in the 97/23/CE directive, Article 1, paragraph 2.1.3.

Associated electronics

CIP / CIP II: Battery powered volumetric counter.
CP ... CH420: 2-wire analog transmitter with flow rate and volume indication.

HART protocol optional.

MC01: Flow rate and volume indicator with relay output for batching.
MT02: Volume counter with relay output for batching.
DFD2: Frequency divider.
CI420: Analog transmitter.
APTM44: Pulse converter for the pickup signal.

Advertising