Troubleshooting – Tecfluid TM Series User Manual

Page 19

Advertising
background image

19

10

TROUBLESHOOTING

Problem

Probable cause

Solution

The associated
electronics does not
totalize

Blockage or friction of the
turbine propeller by particles

Install a filter according to
specification (maximum mesh
size = 200 µm).

Damaged pickup

Change the pickup

Disconnected cables between
the turbine and the associated
electronics

Check the cable connection

The associated
electronics totalize less
than the actual volume

Blockage or friction of the
turbine propeller by particles

Install a filter according to
specification (maximum mesh =
200 µm).

The associated
electronics totalizes
more than the actual
volume

Presence of air pockets

Control the minimum tank level.
Provide an air degasser
upstream of the turbine if air
intakes can be expected.

Excessive emptying of storage
tanks

The pipe is not completely full

Make sure that the pipe is
completely full, for example,
installing the flowmeter in a
vertical pipe with upwards flow

Straight pipe sections before
and after the flowmeter have not
been kept

Check that there are enough

straight pipe sections as
indicated in point 3.4.

The flow rate indicated by
the associated equipment
is unstable