Device name, Snmp setting, Ip settings – Teletronics TT 2400 User Manual

Page 27: Security

Advertising
background image

Device Name


Device Name

This is the name that the bridge will use to identify itself to external configuration and IP address programs. This is not
the same as the SSID. It is okay to leave this blank if you are not using these programs.

SNMP Setting



SNMP enabled

Option to enable or disable SNMP support


Read only community

The SNMP Read-only Community string is like a user id or password that allows access to a router's or other device's
statistics. InterMapper sends the community string along with all SNMP requests. If the community string is correct, the
device responds with the requested information. If the community string is incorrect, the device simply discards the
request and does not respond.

Factory default setting for the read-only community string is set to "public". It is standard practice to change all the
community strings so that outsiders cannot see information about the internal network. (In addition, the administrator
may also employ firewalls to block any SNMP traffic to ports 161 and 162 on the internal network.)

Change this value to have InterMapper use the new string when querying SNMP devices.

IP Settings


IP Address Mode

Static

o Manually setup an IP for this device.

DHCP

o Set up the bridge as a DHCP client which will pick up an IP from a DHCP server.



Default IP address

The default Client Bridge Mode IP address: 192.168.10.241


Default subnet mask

The factory subnet default value is 255.255.255.0


Default gateway

The factory gateway default address is 192.168.10.1