Connect to craft port, Terminal parameters, Logging on – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 16: Bus compatibility

Advertising
background image

DCSU 2911 Quick Set-Up

2-2

Verilink DCSU 2911 User Manual

Connect to Craft

Port

Connect the modular (RJ-11) end of the Craft cable to the port
labeled L

OCAL

on the NCM front panel. Connect the other end of the

Craft cable to your PC or terminal. If your PC has a DB-9 COM port
connector, use a standard PC-AT serial cable to complete the
connection.

Terminal

Parameters

Set your terminal, or terminal program, to

19.2 kbit/s

8 data bits

no parity

one stop bit

no flow control

NOTE: For the most effective and efficient set-up, have all required

planning data such as your intended use, network (telco) provider

specifications, channel and line requirements, circuit

configurations, and other important information handy. For your

convenience, worksheets are provided in the manual, AS2000: The

Basics,

Chapter 2—Site Planning

.

Logging On

1. Press E

NTER

to display the pSH+> prompt and type “craft”.

2. Press E

NTER

to display the NCM Main Menu.

If the NCM Main Menu display (

Figure 2-2)

shows the DCSU in the

proper shelf/slot position, continue with the configuration tasks.

The default password for the NCM gives the user Access Level 2
permissions. For a higher access level, see the NCM 2000 User
Manual
.

Bus

Compatibility

If there is no indication of the DCSU on the “shelf map” on the NCM
Main Menu, the modules may be assigned to different busses on
the shelf midplane.

NCMs are sent out with the C bus as the default bus. Other modules
are sent out with the A bus as a default.

Assign the DCSU to the same bus as the NCM. To assign the bus,
use the DCSU’s Craft port:

1. Connect the Craft cable to the Local port on the DCSU module.

2. At the

YOUR PASSWORD?

YOUR PASSWORD?

YOUR PASSWORD?

YOUR PASSWORD? prompt, press E

NTER

. The DCSU Main

Menu displays.