Manufacturing info, Display alarm buffers -18, Manufacturing info -18 – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 64

Advertising
background image

DCSU 2911 E1 Craft Interface

4-18

Verilink DCSU 2911 User Manual

Display Alarm

Buffers

To display the alarm buffer, enter O in the Net Port Alarm Menu.
The Alarm Buffer shows all major and minor alarms that have
occurred at each port. When an alarm is cleared, the time stamp
changes to reflect the time the alarm was cleared.

Figure 4-14 Alarm Buffer

When finished reviewing the alarm information, enter X to return to
the Main Menu. For example, in the sample display above, a major
alarm was reported on the DCSU 2911 in Shelf 1, Slot 1 at 6:38 pm.
It was caused by errors exceeding the AIS Threshold at port 1 of
this application module.

Manufacturing

Info

To display information on your firmware versions and CIM types,
choose I from the Main Menu.

Figure 4-15 Manufacturing Information

Sn

Severely Errored Second (SES) 15 min. Threshold/SES 24 hr. Threshold:

Select a threshold level.

15 minute

Threshold:

1—900

0 to disable

24 hour

Threshold:

1—86400

0 to disable

In

Bit Error Rate (BER) Threshold: Select a threshold level. Selecting

10

-9

will report more errors than 10

-4

.

Threshold:

1) DISABLE

2) 10E-4

3) 10E-5

4) 10E-6

5) 10E-7

6) 10E-8

7) 10E-9

X

Exit the Net Port Alarm Threshold Configuration Menu

Command

Description

Options

[1,1] DCSU 2911 > o

DCSU 2911 [1,1] AIS Cleared port 1 11-09-96 18:36:50

DCSU 2911 [1,1] AIS Major Alarm port 1 11-09-96 18:36:33

Press enter to continue

MANUFACTURING INFORMATION

Main Card CIM

Revision RM) 1 RC)

Date DM) 10/14/96 DC) 11/10/96

Serial number SM) 00594698 SC) 00486749

Manuf. Part No. MM) 310101776002 MC) 3111017323

Cage Code CM) OJE20 CC) OJE20

Type TM) DUAL CSU TC) CIM29001

Press enter to continue