Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 41

Advertising
background image

DCSU T1 Craft Interface

Verilink DCSU 2911 User Manual

3-19

C

Configure Thresholds: To disable any or all alarm conditions, enter a

threshold value of 0. To enable a condition, specify any non-zero

threshold value.

Refer to

Table

3-11

for

details on the

configuration

parameters.

S

Alarm Status: Displays the counts and intervals of the LOF, LOS, RAI, AIS,

BPV, ES, and SES registers.

Options:

R) Resets Counters: Restarts the values of the LOF, LOS, RAI, AIS, BPV, ES

15 minute, ES 24 hours, SES 15 minute, and SES 24 hour counters. It

resets their values to 0.

X) Exits the Net Port Alarm Threshold Status Menu

R) Resets the

counters

X) Exits the

menu

M

Disable/Enable Alarm Monitor: Use this option to either activate or

deactivate monitoring shelf alarms.

Toggles

between

Enable and

Disable

O

Display Alarm Buffer: Displays major and minor alarms.

Minor: These alarms do not affect traffic along the network line.

Major: These alarms indicate that performance is seriously affected, for

example, a network line failure. It prevents data from being reliably

transmitted across the circuit.

This option also shows any alarms that have been cleared.

Tn

Set Default Thresholds: Use this option to load the factory default

threshold settings.

Yes or No

(Y/N)

X

Exit the Net Port Alarm Menu

Command

Description

Options