Applying silicon dielectric compound – Wavetronix SmartSensor HD (101-0415) - User Guide User Manual

Page 17

Advertising
background image

16

CHAPTER 1 INSTALLING THE SMARTSENSOR HD

Note

The side-to-side alignment will eventually be fine-tuned for better accuracy using
SmartSensor Manager HD (SSMHD). That step will be addressed in Chapter 6, after
SSMHD has been installed.

Side-to-side alignment should

be perpendicular

Figure 1.5 – Side-to-side Positioning

Applying Silicon Dielectric Compound

Use the following steps to correctly apply the silicon dielectric compound:
1 Tear the tab off of the tube of silicon dielectric compound.

2 Squeeze about 25% of the silicon into the connector at the base of the SmartSensor HD

(see Figure 1.6). Be sure to wipe off any excess compound.

Figure 1.6 – Applying Silicon Dielectric Compound