Before Getting Started

AVTrac • Before Getting Started

4

AVTrac can be installed before new carpeting is fitted or retrofitted under preexisting carpet. It can also be installed in

new construction before the drywall and carpeting is in place. Retrofitting the track in a space with existing carpeting

and furniture requires some extra preparation to remove the carpet and prepare the floor for laying the track.
Before installing the AVTrac, determine whether the installation will be in new construction, under preexisting carpet

tiles or under preexisting carpet rolls, and follow the appropriate installation instructions (see page 7). Read and follow

all instructions carefully.

In-Wall Cable Routing Considerations

Locate a convenient junction box in the wall or ceiling for power. The AC power module is rated at 15 A, maximum,

and no fuse is used on the box. Extron recommends that the AC conduit is connected to a junction box that is wired directly

to a 15 A main circuit.
Cables should be run in walls that have drywall cavities. The wall should be free of windows, studs, pipes, or other

obstructions that could hinder cables runs (see the figure below).

Extron AVTrac™
Floor Mount Raceway System

Speakers

AC Junction Box

Projector

Studs

Window

LAN

Planning

Floor Considerations

AVTrac is designed to be installed only underneath commercial grade carpeting 1/4" to 5/16" (0.6 to 0.8 cm) in

thickness. It can be installed under new or preexisting carpet tile or carpet roll.
AVTrac is not designed to be installed under vinyl composite tile (VCT).

N

All structural steps and electrical installation should be performed by qualified personnel in accordance with

local and national building codes and/or local and national electrical codes.