Type tests and environmental conditions – Westermo DDW-222 User Manual

Page 10

Advertising
background image

10

6642-22203

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz), 80 – 1000 MHz
10 V/m 80% AM (1 kHz), 1400 – 2100 MHz
5 V/m 80% AM (1 kHz), 2100 – 2500 MHz
1 V/m 80% AM (1 kHz), 2500 – 2700 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency mag-
netic field

EN 61000-4-8

Enclosure

300 A/m

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Voltage dips and inter-
ruption

EN 61000-4-29

DC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

Radiated
emission

EN 55022

Enclosure

Class A

FCC part 15

Class A

Conducted emission

EN 55022

DC power ports

Class B

Dielectric strength

EN 60950

Signal port to other
isolated ports

1500 Vrms 50 Hz 1 min

Power port to other isolated
ports

1500 Vrms 50 Hz 1 min

Temperature

Operating

-40 to +70ºC

Storage & Transport

-40 to +70ºC

Maximum surface temperatur

135 ºC (temperatur class T4)

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Reliability prediction
(MTBF)

MIL-HDBK- 217F Operating

700 000 hours @ 25°C

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Enclosure

UL 94

Aluminium/Zink

Flammability class V-0

Dimension W x H x D

134 x 105 x 122 mm

Weight

1.5 kg

Degree of protection

IEC 529

Enclosure

IP40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail