Westermo RM-455U-D User Manual

Page 26

Advertising
background image

Chapter Two

Installation

Man_455U-D Rev 3.04

Page 27

2.4.2 RS232 Configuration Port

The serial port is a 9 pin DB9 female and provides configuration and diagnostics of both the
local module and of other modules in the system wile the primary RS232 port is active. This
port is wired as a DCE according to EIA-561. The following table describes the connections
required to connect to a PC serial port. The highlighted entries in this table are those essential
for operation of the Configuration port.

2.4.3 RS485 Serial Port

The RS485 port provides for communication between
the 455U-D unit and its host device using a multi-
drop cable. Up to 32 devices may be connected in
each multi-drop network.

As the RS485 communication medium is shared,
only one of the units on the RS485 cable may send
data at any one time. Thus communication
protocols based on the RS-485 standard require
some type of arbitration. RS485 is a balanced,
differential standard but it is recommended that shielded, twisted pair cable be used to
interconnect modules to reduce potential RFI. It is important to maintain the polarity of the
two RS485 wires. An RS485 network should be wired as indicated in the diagram below and

terminated at each end of the network with a 120 ohm resistor. On-board 120 ohm resistors
are provided and may be engaged by operating the single DIP switch in the end plate next to

RJ-45

Pins

Modem Function

EIA-561 Signal Name

1 None

Ring

Indicator

2

None

Data Carrier Detect

3

Input

Data Terminal Ready

4 Common

Signal

Common

5

Output

Receive Data (from Modem)

6

Input

Transmit Data (to Modem)

7

None

Clear to Send

8

None

Request to Send

HOST

455U-D

HOST

RS485 CONNECTIONS

Advertising