Westermo RM-455U-D User Manual

Page 73

Advertising
background image

455U-D Radio Modem

User Manual

Page 74 © May 2010

#E0

Disable security encryption

#E1

Enable security encryption on transmitted messages

#E2

Enable security encryption on transmitted messages and enforce encryption on
received msgs.

AT#N

Enter Module Serial Number (11 characters Max) (Requires Radio Access AT#R
to change).

AT#O

Control digital I/O point

#O0

Turn digital I/O point off (And enable as an input)

#O1

Turn digital I/O point on

#O2

Digital I/O point reflects communications link

#O5

Dual Redundancy – Change from Primary to Secondary

#O6

Dual Redundancy – Change from Secondary to Primary

AT#P

Set the Remote Access Password. This password must be entered by a remote
user before accessing the module over the radio (Also #A1 must be set).

AT#R

Enter Radio Access Password – Enables radio commands until next reset.

AT#S

Enter AES Security key.

AT#V

Enter Hardware Revision (7 characters Max) (Requires Radio Access AT#R to
change).

AT&Axx

RS-485 Serial port Character Type (Data bits, Stop bits, Parity)

0

8 data, No parity, 1 Stop Bit

1

8 data, No parity, 2 Stop Bits

2

7 Data Bits, Even Parity, 1 Stop bit

3

7 Data Bits, Odd Parity, 1 Stop bit

4

8 Data Bits, Even Parity, 1 Stop bit

5

8 Data Bits, Odd Parity, 1 Stop bit

AT&Bxx

RS-232 Serial port Character Type

0

8 data, No parity, 1 Stop Bit

1

8 data, No parity, 2 Stop Bits

2

7 Data Bits, Even Parity, 1 Stop bit

3

7 Data Bits, Odd Parity, 1 Stop bit

4

8 Data Bits, Even Parity, 1 Stop bit

5

8 Data Bits, Odd Parity, 1 Stop bit

AT&C

Data Carrier Detect (DCD) Control.

&C0

DCD Always on.

Advertising