Westermo RM-455U-D User Manual

Page 45

Advertising
background image

455U-D Radio Modem

User Manual

Page 46 © May 2010

If configuraing using Hayes commands the Dual Redundancy is set via the AT#O command
(“Control digital I/O function”).

 Force a changeover from primary to secondary, use command AT#O5.
 Force a changeover from secondary to primary, use the command AT#O6.
 Status of the Dual Redundant system is displayed in register S33.

S33 Value

Dual Redundant State

2

Active Primary

3

Active Secondary

4

Active Primary – no secondary detected

5

Inactive Primary

6

Inactive Secondary

3.8.1 Single Host Device

If the 455U redundant pair are connected to a single host device, they should be connected
via RS485 - both 455U units will hear all data messages, but only the active 455U unit will
send messages.

3.8.2 Redundant Host Pair

If the host device is duplicated as a redundant pair, with an individual host connected to an
individual 455U, then RS232 should be used - the 455U will receive and send serial
messages, however only the active 455U will transmit via the radio.

3.8.3 Dual Redundanct Control Connection

The DIO channels on the two units are connected - this connection forms the Dual
Redundant Control Connection.

RS232

RS232

RS485

REDUNDANT PAIR WITH SINGLE HOST

REDUNDANT PAIR WITH REDUNDANT HOSTS

USING

RS485

USING

RS232

Advertising