Alternate procedure – Adjust RM-80 network settings using serial
port(assuming configuration PC is on existing network)

a) Open terminal program with settings with data rate 19200bps, 8 data bits, 1

stop bit and no parity.

b) Set dipswitch to SETUP

c) Connect straight through serial cable to RM-80 and power up unit.

d) When prompted, strike the Enter key to abort automatic boot

e) Set IP address of RM-80 to 192.168.0.200 with command bip 192.168.0.200

f) Set netmask of RM-80 to 192.168.0.200 with command bnm 255.255.255.0

g) Set gateway address of RM-80 to 192.168.0.1 with command bgw 192.168.0.1

h) Set dipswitch to RUN

i) Reset RM-80 with reset command.

j) Open configuration webpage with Internet Explorer at address

http://192.168.0.200/
When prompted for password, enter default username “user” and password
“user”
Enter “Quick Start”, and select Access Point.
IP address should be 192.168.0.200
Enter a System Generator String
Select the Radio Encryption required.
Save the changes.

Client 1 Configuration

Perform the same configuration steps as the Access Point configuration with the follow-
ing differences:

… set IP address of RM-80 to 192.168.0.201

… set the Operating Mode to Client.

Ensure the same System Generator String is used and the same Radio Encryption meth-
od is selected.

Client 2 Configuration

… As above, but use IP address 192.168.0.202