&En Ð Data Dial Options

This command stores the current profile and enables or disables the dialling with data
from DTE. The modem will dial the address stored with AT&Z0=....

&E0

Disable dial with data.

&E1

Enable dial with data.

Observe that this will take the modem to data-mode and all incoming characters from DTE will be
interpreted as a dial command. There are two possibilities to leave data mode.
Number one is to use the escape sequence when the modem is connected and then disable the dial
with data (&E0).
Another possibility is to use switch S4:8 which works as a reset switch and will disable the dial with
data (&E0). The modem will be reset on a ON to OFF to ON sequence on switch S4:8.
Switch S4:8 can only be used when the modem is disconnected from the line.

&F Ð Recall (restore) factory configuration

This command restores the original factory setting of all parameters and S-registers.
When the modem is restarted the parameter set by the customer will be restored.
By using the &W command the factory setting will be valid also after restart of the
modem.

H Ð Disconnect (hang up)

This command initiates a hang up sequence.

&Kn Ð Flow control

This command defines the DTE/DCE (terminal/modem) flow control mechanism.

&K0

Disables flow control (default).

&K3

RTS/CTS flow control.

&K4

XON/XOFF flow control (with characters specified in S-register 32 and 33).

O Ð Return to On-Line Data Mode

This command returns the modem to data mode when the modem has entered the on-line
command mode. Observe that this command is only possible when a connection is estab-
lished and the escape sequence has been entered.

Qn Ð Result Codes Control

This command enables or disables the result codes to the DTE.

Q0

Enables result codes to DTE (default).

Q1

Disables result codes to DTE.