Chapter four – Extron electronic MKP 2000 User Manual

Page 19

Advertising
background image

MKP 2000 Remote Control Panel • Local Operation

Local Operation, cont’d

MKP 2000 Remote Control Panel

4

Chapter Four

SIS Operation

RS-232 Links

Ethernet Link

Host-to-MKP Instructions

MKP-Initiated (Unsolicited) Messages

MKP Error Responses

Using the Command/Response Table

3-10

Performing a hard reset

The hard reset function restores the MKP to the original factory
default settings, including the default (factory) firmware
configuration and the default IP settings. A hard reset performs
all of the reset-whole-MKP functions, absolute reset functions,
and

erases all user-installed software or firmware. Perform a

hard reset as follows:

Ensure that you have backed up any locally-created
HTML, JavaScript, or other files that you have uploaded
to the MKP’s user file space before you perform the hard
reset. A hard reset will erase all locally-created files
from the MKP.

1

.

If necessary, turn off power to the switcher.

2

.

Press and hold the Reset button on the rear panel while
you apply AC power to the MKP (figure 3-5).

Power

R

R

Press and hold the
Reset button while you
apply power to the MKP.

The LED flashes
on and off.

Release the Reset button.

Figure 3-5 — Hard reset

Advertising