Sis operation, cont’d, Mkp error responses, Using the command/response table – Extron electronic MKP 2000 User Manual

Page 21

Advertising
background image

MKP 2000 Remote Control Panel • SIS Operation

MKP 2000 Remote Control Panel • SIS Operation

SIS Operation, cont’d

This message means that the switcher requires an administrator
or user level password before it will perform the commands
entered via this link. The switcher repeats the password
message response for every entry other than a valid password
until a valid password is entered.

Login Administrator

Login User

The switcher initiates the login message when a correct
administrator or user password has been entered. If the user
and administrator passwords are the same, the switcher
defaults to administrator privileges.

MKP Error Responses

When the switcher receives an SIS command and determines
that it is valid, it performs the command and sends a response
to the host device. If the switcher is unable to perform the
command because the command is invalid or contains invalid
parameters, the switcher returns an error response to the host.
The error response codes are:

E01 — Invalid input channel number (too large)
E10 — Invalid command
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E24 — Privilege violation (Ethernet, Extron software only)
E99 — Invalid or no response from target switcher

Using the Command/Response Table

The command/response table begins on page 4-8. Lower case
letters are acceptable in the command field except where
indicated for the gain and attenuation commands. The table
below shows the hexadecimal equivalent of each ASCII
character used in the command/response tables.

ASCII to HEX Conversion Table

Space

The MKP always redirects a subset of valid matrix switcher-
specific SIS commands on its Ethernet port and, if configured in
pass-through mode, on its Switcher RS-232 port.

It is not the purpose of this manual to define in detail the
passed-through matrix switcher-specific SIS commands.
Refer to the applicable matrix switcher’s manual.

Symbols are used throughout the tables to represent variables in
the command/response fields. Command and response
examples are shown throughout the MKP SIS commands table.

4-5

4-4

Advertising