AIRLESSCO SP200 User Manual

Page 12

Advertising
background image

Setup

12

3A0994E

2.

Separate prime tube (smaller)
from suction tube (larger).

3.

Place prime tube in waste pail.

4.

Submerge suction tube in
water or flushing solvent.

5.

Turn Prime/Spray Valve to
PRIME.

6.

Plug sprayer in a grounded outlet.

7.

Turn power switch ON.

8.

Align setting indicator with
Prime/Clean setting on Pres-
sure Control knob until pump
starts, page 10.

9.

When sprayer starts pumping, flushing solvent and
air bubbles will be purged from system. Allow fluid to
flow out of prime tube, into waste pail, for 30 to 60
seconds.

10. Turn power switch OFF.

11. Transfer suction tube to paint

pail and submerge suction tube
in paint.

12. Turn power switch ON.

13. When you see

paint coming out of
prime tube:

a.

Point gun into
waste pail.

b.

Unlock gun
trigger lock.

c.

Pull and hold
gun trigger.

d.

Turn
Prime/Spray
valve to
SPRAY.

14. Continue to trigger gun into waste pail until you see

only paint coming out of gun.

15. Release trigger.

Engage trigger
lock.

16. Transfer prime

tube to paint pail
and clip prime
tube to suction
tube.

NOTE: Motor stopping indicates pump and hose are
primed with paint. If motor continues to run the sprayer
is not properly primed. To reprime repeat step 8.

ti2039a

ti9652a

ti9651a

ti9346a

ti5580a

ti9718b

ti2810a

ti9653a

ti5580a

(Mustang 2)

ti15979a

ti15980a

(ASM 500)

ti9345a

(Mustang 2)

ti15978a

ti15981a

(ASM 500)

Advertising
This manual is related to the following products: