Shutdown and Cleaning

18

3A0994E

Shutdown and Cleaning

Pail Flushing

For short term shutdown periods (overnight to two
days) refer to Short Term Storage, page 23.

For flushing after spraying oil-based coatings, use
compatible oil-based flushing fluid or mineral spirits.
Read Priming and Flushing Storage Fluid, page 11.

For flushing after spraying water-based coatings,
use water. Read Priming and Flushing Storage
Fluid, page 11 or Power Flush, page 20.

1.

Relieve pressure, page 10.

2.

Remove tip and guard assembly from gun and place
in flushing fluid.

3.

Lift suction tube and prime tube from paint pail. Let
them drain into paint pail for a while.

4.

Separate prime tube (smaller) from
suction tube (larger).

5.

Place empty waste and
water or solvent pails side
by side.

6.

Place prime tube in waste pail.

7.

Submerge suction tube in
water or flushing solvent.

8.

Turn pressure control knob to
the Prime/Clean setting.

9.

Turn power switch ON.

10. Flush until approximately 1/3 of the flushing

fluid is emptied from the pail.

11. Turn power switch OFF.

ti2039a