Connecting to an nmea 2000, Network – Airmar 200WX—Ultrasonic WeatherStation® Instrument User Manual

Page 17

Advertising
background image

17

Connecting to an NMEA 2000

®

Network

CAUTION: Only two termination resistors are required on an NMEA 2000
network. More than two will degrade the bus performance.

Route the WeatherStation cable to the NMEA 2000 network. Plug the NMEA 2000
connector into the network node (see Figure 8). Coil any excess cable and secure
with cable ties to prevent damage.

NOTE: WeatherStation cables longer than 6m (20') have a termination resistor
built into the WeatherStation connector (see Figure 9).

Figure 8. NMEA 2000® WeatherStation Cable [6m (20') shown]

10

WeatherStation

NMEA 2000

network

connector

connector

locator

10

Copyright © 2008 - 2011 Airmar Technology Corp.

Figure 9. NMEA 2000® WeatherStation Cable [10m (33') shown]

10

WeatherStation

connector

NMEA 2000

network

connector

locator

120Ω

termination resistor in connector

10

Copyright © 2009 - 2011 Airmar Technology Corp.