Aluminum wire will void warranty, Electrical requirements and guidelines – Alps Spas XLS Models User Manual

Page 17

Advertising
background image

• From main panel, run 6-2 with ground to outside disconnect.

• Run 6-2 with ground from outside disconnect to spa.

• ALPS SPAS recommends that a 60 AMP 220 GFCI

must be used in disconnect.

• Disconnect must be at least 6 ft. from spa!

• Any of the four panels can be drilled out and removed for

easy electrical entry.

• Wire may be drilled thru bottom consult dealer for

drilling specifications.

• All exposed wire must be INSTALLED IN CONDUIT and have

proper connectors.

• ALPS SPAS is not responsible for any mis-wiring of control panel.

• All models require a 60 AMP GFCI.

ALUMINUM WIRE WILL VOID WARRANTY!

Swim Spa electrical requirements

From main panel install a 60 AMP GFCI 220 breaker.

Run no# 6-3 with ground. (2 hots, neutral and ground - 4 wires)

Install an outside disconnect (with 60 AMP GFCI Breaker)

No closer than 6 ft from SPA!

Hard wire from disconnect to Swim Spa control panel.

U.S. Only / For European wiring diagram please consult with your dealer.

alpsspas.com

ELECTRICAL REQUIREMENTS AND GUIDELINES