If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that
the device be wired as shown in Fig 1. This will allow the original on/off rocker switch to be
used incase the device that is mounted to the wall is inoperable.
Note: Archgard Industries does not manufacture, or sell any wall switch or wall thermostat, and
will not extend warranty to them.

OPTIONAL WALL SWITCH OR THERMOSTAT

Thermostat / wall switch wire table

Recommended Maximum Lead Length

for two wires

Wire Size

Max. Length

14 GA.

50 Ft. (15.24 M)

16 GA.

32 Ft. (9.75 M)

18 GA.

20 Ft. (6.9 M)

20 GA.

12 Ft. (3.65 M)

22 GA.

9 Ft. (2.74 M)

Fig. 1

VALVE CONNECTION for MILLIVOLT VALVE

CAUTION: DO NOT CONNECT ANY AC VOLTAGE TO THE GAS VALVE.

A

ELECTRODE

B

THERMOPILE

C

PILOT CAP

D

THERMOCOUPLE

PILOT ASSEMBLY

OPTIONAL WALL

SWITCH. WALL

THERMOSTAT OR

HAND HELD REMOTE

CONTROL

THERMOCOUPLE LEAD

PILOT SUPPLY TUBE

B

A

C

D

WIRE TO