Venting instructions – Archgard 3600-DVTR24N User Manual

Page 27

Advertising
background image

Optima 3600 –1

27

This appliance will not function without being connected to a proper venting system.
This appliance may use 4" & 7" gas flex vents with Optima 3600 listed vent
components, Selkirk (Direct-Temp) 4” x 6⅝”” venting or Simpson Dura-Vent 4" x 6⅝"
direct vent system with Simpson Dura-Vent adapter 999-DV-SDA. Read the
manufacturer’s installation instructions before installing the venting system.

Typical Installation

24”(min) vertical vent pipe on top of the appliance,

One 90

o

elbow, and up to 24” (max) horizontal run to the outside.

The termination required is either Archgard part# 999-DV-HTC, Simpson Dura-
Vent part# 984 or Selkirk part# 4DT-HC.


Other installations

Up to 4 - 90

o

elbows, or equivalent, maximum.

Minimum 2’ (610mm) straight length between bends.

The total vertical height up to 40’ (12.2m) maximum.

The total horizontal run up to 20’ (6.1m) maximum.

Note: 4’ (1.2m) minimum of vertical height required.


Note: Maximum vent lengths may be subject to local codes.

For best venting performance, here are some general venting rules:

1. Maintain a minimum of 1” (26 mm) clearance to combustibles from the outside

surfaces of vertical vents and minimum of 1” (26 mm) sides and bottom, and
2” (51 mm) from top surfaces of horizontal vents. Always use a wall thimble when
passing through combustible construction.

2. Observe all local code restrictions, if any, regarding the installation of this type of

gas appliance.

3. Observe the vent height and length restrictions given in this manual.
4. Never slope horizontal vents downwards.
5. Maintain at least an upward slope of ¼” (7 mm) for every 1 ft (305 mm) of

horizontal vent.

6. Terminate the vent with a termination certified for use with this appliance.
7. Support horizontal vent every 3 ft (915 mm) to prevent it from sagging.

VENTING INSTRUCTIONS

TOP VENT