Installation instructions – Archgard 3600-DVTR24N User Manual

Page 29

Advertising
background image

Optima 3600 –1

29

TOP VENT VERTICAL VENTING

Restrictor #1

VENT RESTRICTORS FOR TOP VENT INSTALLATIONS

All top vent installations require the use of Restrictor #1 (40%).
The restrictor is installed in the exhaust of the appliance.

The rear vent configurations do not require a vent restrictor.

Example 1

V Value
= 3A (12') + 1C (3') = 15'
H Value = 2B (4') =4'

V Value = Total length of all vertical sections in feet.
H Value = Total length of all horizontal sections in feet.

Note:

For H & V values for 45º venting see Chart IV

Elbows are not counted in H or V values

Vent chart starts from the top of the unit

CHART IV

INSTALLATION INSTRUCTIONS

Advertising