Pyramid probes: new core inspection – Cascade Microtech Pyramid Probes User Manual

Page 6

Advertising
background image

PN 153-690-3

www.cascademicrotech.com

Pyramid Probes: New Core Inspection • 6

Membrane

Surface

Have any particles penetrated the membrane (poly2) surface after the thinfilm fabrication

process?

The presence of External Embedded

Particles is unacceptable on a new core.

Were any particles created or formed below the membrane (poly2) surface during the

thinfilm fabrication process?

Internal Embedded Particles are acceptable as long as they pass all other specifications.

Polyimide may appear rough and discolored around the beams, component attachment pads, or any other

plated metal area forming part of the membrane surface:

• On the probe face, this is acceptable up to 200µm radius around the beams or other plated

metal area forming part of the membrane surface.

• On the wings and the interface area, this is acceptable in all areas.

Unacceptable

Cross section with external

embedded particle.

Acceptable

Cross section with internal

embedded particle

Acceptable

Pyramid Probes: New Core Inspection