18

[RB1-Ten-GigabitEthernet1/0/3] quit

[RB1] interface ten-gigabitethernet 1/0/4

[RB1-Ten-GigabitEthernet1/0/4] trill enable

[RB1-Ten-GigabitEthernet1/0/4] trill link-type trunk

[RB1-Ten-GigabitEthernet1/0/4] quit

[RB1] interface ten-gigabitethernet 1/0/5

[RB1-Ten-GigabitEthernet1/0/5] trill enable

[RB1-Ten-GigabitEthernet1/0/5] trill link-type trunk

[RB1-Ten-GigabitEthernet1/0/5] quit

# Configure RB 2 through RB 5 in the same way RB 1 is configured.

3.

Configure the downlink ports of distribution layer devices:
# Enable TRILL globally on RB 6, enable TRILL on downlink port Ten-GigabitEthernet 1/0/1
through Ten-GigabitEthernet 1/0/5 of RB 6, and configure these ports as trunk ports.

<RB6> system-view

[RB6] trill

[RB6-trill] quit

[RB6] interface ten-gigabitethernet 1/0/1

[RB6-Ten-GigabitEthernet1/0/1] trill enable

[RB6-Ten-GigabitEthernet1/0/1] trill link-type trunk

[RB6-Ten-GigabitEthernet1/0/1] quit

[RB6] interface ten-gigabitethernet 1/0/2

[RB6-Ten-GigabitEthernet1/0/2] trill enable

[RB6-Ten-GigabitEthernet1/0/2] trill link-type trunk

[RB6-Ten-GigabitEthernet1/0/2] quit

[RB6] interface ten-gigabitethernet 1/0/3

[RB6-Ten-GigabitEthernet1/0/3] trill enable

[RB6-Ten-GigabitEthernet1/0/3] trill link-type trunk

[RB6-Ten-GigabitEthernet1/0/3] quit

[RB6] interface ten-gigabitethernet 1/0/4

[RB6-Ten-GigabitEthernet1/0/4] trill enable

[RB6-Ten-GigabitEthernet1/0/4] trill link-type trunk

[RB6-Ten-GigabitEthernet1/0/4] quit

[RB6] interface ten-gigabitethernet 1/0/5

[RB6-Ten-GigabitEthernet1/0/5] trill enable

[RB6-Ten-GigabitEthernet1/0/5] trill link-type trunk

[RB6-Ten-GigabitEthernet1/0/5] quit

# Configure RB 7 through RB 9 in the same way RB 6 is configured.

4.

Configure the uplink ports of the distribution layer devices:
# Enable TRILL on uplink ports Ten-GigabitEthernet 1/0/6 and Ten-GigabitEthernet 1/0/7 of RB
6.

[RB6] interface ten-gigabitethernet 1/0/6

[RB6-Ten-GigabitEthernet1/0/6] trill enable

[RB6-Ten-GigabitEthernet1/0/6] quit

[RB6] interface ten-gigabitethernet 1/0/7

[RB6-Ten-GigabitEthernet1/0/7] trill enable

[RB6-Ten-GigabitEthernet1/0/7] quit

# Configure RB 7 through RB 9 in the same way RB 6 is configured.